Www.energystar.gov
Lumens per Fixture Total Installed Wattage, W Exterior Lighting Garage, Corridors, Lobbies & Stairs Energy Usage per Square Foot of Conditioned Area Btu/SqFt Under Ground Garage Above Ground Garage Parking Lot Gas Energy Average ... Doc Viewer
Www.consumersenergy.com
Heater must be rated between 500,000 BTU/H and 2,000,000 BTU/H. Must have an on/off switch and have no pilot light. Incentive is calculated per square foot of lighting controlled. Occupancy sensors installed on LED refrigerated lighting must be ≥ 35 lumens per watt and ≥ 72 CRI. ... Get Document
ABSORPTION UNIT Is An Absorption Refrigeration
To the ballast or other auxiliary device (e.g. transformer); expressed in lumens per. and is expressed in Btu per square foot per °F. the section without an overhead roof is considered a parking lot instead of a parking garage. Precision commercial or industrial work is a room ... Retrieve Doc
Efficient Motors
From Impact Evaluation of Orange & Rockland’s Small Commercial Lighting Program, 1993. O&R hours for “High-Performance” or “Super” T8 lamp/ballast systems have higher lumens per watt than standard T8 WSFeffic = the actual installed lighting watts per square foot or linear ... Content Retrieval
Creating Energy-Efficient Communities In California: A ...
LPW Lumens per Watt (lights) MMBtu Million Btu MEF Minimum Energy Factor of Dishwasher (per CEC sf square foot Lighting – Parking Garage Title 24 T24 Mandatory T24 Prescriptive ... Fetch Doc
Fortress.wa.gov
Those with a peak design rate of energy usage less than 34 Btu/h · ft2 (10.7 W Portions of roofs that are ballasted with a minimum stone ballast of 17 pounds per square foot (psf) (74 kg of wall surface area if the material weight is not more than 120 pounds per cubic foot (pcf ... View Doc
Www.dte-yourenergysavings.com
Exterior or Garage HID to LED/Induction Lighting Retrofit Incentive is per square foot of pool surface area. Replacement lamps must have a minimum efficacy of 35 lumens per watt.Replacement lamps must be 20 Watts or less. ... Visit Document
Equipment Efficiency Guide
> 75W input watts or ≥ 5,000 lumens $250 $100 PARKING GARAGE or Architectural ≥ 1,000 lumens $100 $40 Exterior Lighting Requirements Btu/Hour Tons Eligibility Requirements Minimum Efficiency SEER / EER / IEER ... Read More
Www.dcseu.com
COMMERCIAL LIGHTING FORM 6. CUSTOMER INFO & AGREEMENT 5. TERMS & CONDITIONS (2) 4. and Retrofit Kits >= 30 input watts OR >= 2000 lumens Parking Garage/Canopy Fixtures and Retrofit Kits < 30 input watts Parking Garage/Canopy Fixtures and Retrofit (per linear foot) ... Retrieve Doc
1. 60 lumens per watt for lamps over 40 watts, by the appropriate unit lighting power allowance, in watts per square foot, for the use as specified in Table 15-1a or Table 15-1b, Figures in parenthesis are equivalent Btu per hour per square foot. ... Fetch Full Source
2009 IECC
35 pounds per square foot (170 kg/m2 of insulation having a conductivity not exceeding 0.27 Btu per inch/h ft2 building grounds luminaires that operate at greater than 100 watts shall contain lamps having a minimum efficacy of 60 lumens per watt unless the luminaire is ... Fetch Document
COUNTY COUNCIL OF PRINCE GEORGE'S COUNTY, MARYLAND
Fired by oil, gas, or electricity and which does not exceed the following limitation: two hundred thousand (200,000) British thermal units per hour (Btu/hr [one and one-fourth (1 1/4) lumens per square foot] a one will be used to determine the permit fee for all commercial ... Return Doc
FUS-0435*; P-00981628.O; Citizens Tel. Co. Of New York
Under the new standards the lumens produced from a currently available 100 watt bulb must be produced by a bulb with a maximum wattage of 72 watts. For existing commercial lighting, WSFeffic = the actual installed lighting watts per square foot or linear foot. Table 14: ... Read Document
RAJASTHAN RENEWABLE ENERGY CORPORATION LIMITED
Expressed in lumens per watt. Btu/h ft 0F British thermal units per hour square foot per degree Fahrenheit . F Fahrenheit. Ft foot. H hour . HC Heat Capacity. H FT2 0F Btu hour per square foot per degree Fahrenheit per British . H m2 0C/W hour per square meter per Celsius per Watt. ... Access Doc
New Jersey Clean Energy Collaborative
Heating Energy (kWh) Savings = ((CAPYq X EFLHHT)/100,000 BTU/therm) X FFSHT. Cooling Energy (kWh) Savings = FFSCL. Solar Domestic Hot Water (augmenting the per square foot estimates in the protocols will be multiplied by the number of square Prescriptive Lighting for Commercial Customers. ... Content Retrieval
BIDDING DOCUMENTS
A ton of refrigeration is best described as 12,000 BTU per hour and the amount of heat necessary to melt a ton of ice over a 24-hour period. in lumens. The lighting level on a given plane, where one foot candle is equal to one lumens per square foot. ... Retrieve Content
Energy $avings Oppourtunities - Pollution Prevention Office
Etc. Can save over 2.00 per ccf (748 gallons) in sewer costs Typical Energy Cost per Square Foot Industries: $1-6 Voc Rehabs Lighting efficiency = Lumens/watts input; Lumens are usually listed on the lamp or box. Many commercial operations have to take lighting color into account for ... Visit Document
SUSTAINABLE ENERGY STANDARD For The International Energy ...
Commercial buildings shall demonstrate that 5% of the total control of their operation, in w/ft2 or Btu-h/ft2. Site Energy: per square foot by the following factors: Site Energy Factor Electric 3.10 Gas 1.11 Wood 1.00 ... Get Doc
FUS-0435*; P-00981628.O; Citizens Tel. Co. Of New York
For Commercial and Industrial (C&I) lighting, (Gallons-°F) Fixed 8.33 Convention UE Unit Conversion: 1 kWh/3413 BTU Fixed 1/3413 Convention Eff Efficiency of Electric Water Heater Fixed 0.90 2 FED Energy To Demand Factor the per-square-foot estimates in the algorithms will be ... Retrieve Doc
SECTION 13-100
Typically expressed in lumens per watt. [4412] EFFICIENCY (work), electrical, and chemical. Customary measurement units are British thermal units (Btu). ENERGY COST. The total estimated annual cost Walls weighing at least (1) 35 pounds per square foot (170 kg/m2) of wall ... View Document
No comments:
Post a Comment